Water Level Sensor with NO and NC Relay Output: Setup Guide
A practical guide to selecting, wiring, and using a separated-probe water level sensor with NO and NC relay outputs on 10 to 15 VDC for automatic pump control and overflow prevention.

In this guide
A Water level sensor with NO and NC relay output, 10 to 15 VDC automates pump logic by switching a relay when water reaches the sensing point. The controller runs on 10 to 15 VDC, drawing under 100 mA, while contacts handle up to 250 V 10 A AC or 30 V 10 A DC. This allows you to cut power to a filling pump or start a drainage pump automatically. The separated probe keeps electronics dry and places detection exactly where needed.
Short answer
This sensor detects water at a chosen level and flips a relay that interrupts or completes your pump circuit. When water rises to the probe, the relay actuates: the normally closed contact opens to shut off a filling pump, and the normally open contact closes to trigger a drainage pump or an alarm. The controller side needs a 10 to 15 VDC supply drawing under 100 mA, and the relay contacts switch loads up to 250 V 10 A AC or 30 V 10 A DC. Because the sensor is separated from the controller, you mount the probe at the water line and keep the electronics in a dry, protected location.
What you get in one device
A single unit that stops a pump when a tank is full, starts a pump when the level drops, and keeps the wet sensing end physically apart from the relay controller. You choose the behaviour by wiring to the NO or NC contact.
How this sensor controls your pump
The relay inside the controller has two output states, and the one you wire to determines what happens when water hits the probe. When the relay actuates, the normally open contact closes and the normally closed contact opens. That single mechanical action gives you two opposite control paths from one detector.
For overflow protection, you wire your filling pump through the normally closed contact. The pump runs normally while the tank fills. The moment water reaches the sensor, the relay actuates, the NC contact opens, and the pump loses power. The tank stops filling at the level you chose. This is the logic you want for cisterns, storage tanks, and any tank where running dry or overflowing causes damage.
For level maintenance, you wire a drainage or transfer pump through the normally open contact. The pump stays off while water is below the sensor. When water rises to the probe, the relay actuates, the NO contact closes, and the pump starts. This is the logic for sump pumps, basement drainage, and machine rooms where accumulated water needs to be pumped out before it reaches a critical level.
| Contact | State before water reaches probe | State after relay actuates | Typical use |
|---|---|---|---|
| Normally Closed (NC) | Closed, pump runs | Opens, pump stops | Tank filling, overflow prevention |
| Normally Open (NO) | Open, pump off | Closes, pump starts | Sump drainage, high-water alarm |
The sensor includes anti-jamming capability and a rapid response to waves and ripples, which matters in tanks where agitation or splashing could otherwise cause chatter. Normally open contacts suit pumps that empty a tank, while normally closed contacts suit pumps that fill a tank.
Checking compatibility with existing equipment
The relay contacts are rated for 250 V 10 A AC or 30 V 10 A DC, and loads below that range can be switched directly. Before wiring anything, confirm your pump's running current sits within that 10 A ceiling. Check the nameplate on your pump motor for its full-load amperage rating.
Pump motors are inductive loads, meaning they draw a surge of current at startup that can exceed their running amperage. If your pump's running current is close to 10 A, the startup surge may push past the relay rating. For pumps drawing near the contact limit, routing the relay output through an external contactor rated for motor starting is the standard approach. The relay then signals the contactor coil at low current, and the contactor handles the motor load.
Direct switching works when
- Pump running current is well below 10 A
- Load is resistive or lightly inductive
- Voltage matches 250 V AC or 30 V DC ceiling
Use a contactor when
- Pump running current approaches 10 A
- Motor has high startup inrush
- Pump starts frequently under load
If you are automating a garden watering setup alongside this sensor, the same load-checking principle applies to any pump you pair with a sprinkler timer or irrigation controller.
Installation: Separating the wet end from the electronics
The sensor probe and the controller are separate components. You place the probe at the exact water level where you want detection to occur, and you mount the controller where it stays dry and accessible for wiring.
- Mount the sensor probe at your target water lineFix the probe at the height where you want the relay to actuate. For overflow protection, that is near the top of the tank. For sump drainage, place it at the level where water should trigger the pump.
- Keep the controller enclosure away from splashing, waves, and condensation. Mount it above the tank or sump pit where it stays accessible for wiring and inspection.
- Route the sensor cable away from AC power linesRun the low-voltage sensor lead separately from mains-voltage pump wiring. Keeping the two in separate raceways reduces the chance of electromagnetic interference causing false triggers.
- Wire the relay output to your pump circuitConnect the NO or NC contact in series with your pump control circuit, depending on whether you want the pump to start or stop when water is detected. Confirm polarity and contact ratings before applying power.
- Apply 10 to 15 VDC to the controller and testPower the controller with a stable DC supply within the specified range. Manually raise water to the probe and verify the relay clicks and your pump responds correctly.
Power supply requirements
The controller needs a DC supply between 10 and 15 VDC and draws under 100 mA. Use a stable supply so the voltage stays within that range.
A 12 VDC adapter sits in the middle of the operating range. A 15 VDC supply also works and gives you headroom if the cable run between the supply and controller is long enough to cause a voltage drop. Keep the supply within 10 to 15 VDC.
| Parameter | Specification |
|---|---|
| Working voltage | 10 to 15 VDC |
| Custom voltages | Available on request |
Keeping your 10 to 15 VDC sensor wiring physically apart from the AC pump circuit is a practical way to avoid interference. Test the relay response once everything is installed.
If your setup involves monitoring environmental conditions alongside water level, a temperature humidity sensor can round out the picture in a machine room or basement installation.
Common applications and use cases
The Water level sensor with NO and NC relay output, 10 to 15 VDC fits any scenario where you need a relay to change state at a specific water level. The separated construction and dual-contact output make it practical across residential and light commercial settings.
- Basement sump pumps: Wire the NO contact to start the sump pump when water rises to the probe. The pump runs until the level drops, then the relay releases and the pump stops.
- Tank filling and cistern control: Wire the NC contact to a filling pump. The pump runs until water reaches the sensor, then the relay opens and filling stops. This prevents overflow without a separate shut-off valve.
- Garage and warehouse drainage: Mount the probe at the threshold where water accumulation becomes a problem. When water reaches that point, the relay triggers a drainage pump or an alarm.
- Machine room equipment: Use the sensor to detect water or condensate levels in collection trays. The relay can shut down equipment or trigger a warning before a tray overflows into sensitive machinery.
- Base station equipment rooms: Leaking HVAC condensate or raised-floor water detection can trigger alarms or cut equipment power.
For broader home monitoring, you can pair this sensor with a water leak sensor to cover both point-level detection and floor-level leak detection in the same space. If you are building out a larger monitoring system, the sensors category covers additional detection options.
Wiring logic for pump-down versus fill applications
The same hardware serves two opposite purposes depending on which contact you use. Getting this right at the planning stage saves rework later.
| Application | Contact used | Pump state at low water | Pump state at high water |
|---|---|---|---|
| Tank filling (overflow prevention) | NC | Pump runs, tank fills | Relay opens, pump stops |
| Sump drainage (level maintenance) | NO | Pump off | Relay closes, pump starts |
One common mistake is wiring a filling pump to the NO contact by accident. The pump will not run at all, because the NO contact stays open until water reaches the probe. If your pump does not start when you expect it to, check which contact pair you wired to before anything else.
Pre-installation checklist
- Confirm your pump's running current is below 10 A
- Decide fill logic (NC) or drain logic (NO) before wiring
- Source a regulated 10 to 15 VDC power supply
- Plan separate cable routes for sensor leads and AC pump wiring
- Mount the controller above the highest expected water level
- Test the relay response by manually raising water to the probe
FAQ
- Can I get this sensor in a different working voltage?
- Yes. The standard working voltage is 10 to 15 VDC, and other working voltages can be customized.
- How does the sensor handle waves and ripples?
- The sensor includes anti-jamming capability and a rapid response designed for conditions where waves or ripples cross the probe. This reduces false triggering in agitated tanks or environments with splashing.
- Can I use this sensor for both filling and draining?
- Yes. Wire a filling pump to the NC contact to stop it when water reaches the sensor, or wire a drainage pump to the NO contact to start it at high water, depending on your setup.
- What colour is the sensor?
- The product is white.
- Can the relay directly switch a pump that draws close to 10 A?
- The relay is rated for 250 V 10 A AC or 30 V 10 A DC. Pump motors are inductive loads with startup surges, so if your pump's running current is near 10 A, use an external contactor rated for motor starting rather than switching the motor directly through the relay.
Once you have confirmed your pump's current draw, chosen your fill or drain logic, and sourced a stable 10 to 15 VDC supply, the installation comes down to mounting the probe at the right level and keeping the controller dry. Test the relay by raising water to the probe before you walk away from the job.
Water level sensor with NO and NC relay output, 10 to 15 VDC
White
$35.99
Standard shipping 2–4 days